Enhanced ventilation

Possible 3 points

Intent

To minimize moisture problems and occupants’ exposure to indoor pollutants through enhanced exhaust and ventilation systems.

Requirements

Option 1. Enhanced Local Exhaust (1 point)

Use one of the following strategies in every bathroom with a shower, bathtub, or spa (i.e., half-baths are exempt) to control the use of the local exhaust fan:

  • an occupancy sensor;
  • an automatic humidistat controller;
  • a continuously operating exhaust fan; or
  • a delay timer that operates the fan for at least 20 minutes.

AND/OR

Option 2. Enhanced Whole-House Ventilation (2 points)

Install a balanced whole-house ventilation system (not just exhaust only or supply only) that meets the minimum ventilation requirements of ASHRAE Standard 62.2–2010, Sections 4 and 7, or local equivalent whichever is more stringent. Program the system such that it does not exceed the standard’s requirements by more than 10%.

For multifamily buildings, meet the above requirements for all in-unit residential spaces in both options 1 and 2.

Join LEEDuser

Ask questions, share tips, and get notified of new forum posts by joining LEEDuser, a tool developed by BuildingGreen and supported by USGBC!

  • Share on Twitter
  • Share on Facebook
  • Share on LinkedIn
  • Print to PDF
Sample forms

No sample form available for this credit.

View all sample forms

0 commentsLeave a comment

Leave a comment Don't have an account? Create one

You must be signed in to leave a comment.