Entry Type ID Date Applicable Rating System Primary Credit Inquiry (LIs) Ruling (LIs) Related Addenda/LIs Related Resources Campus Applicable Internationally Applicable Country Applicability Reference Guide (Addenda) Page (Addenda) Location (Addenda) Description of Change (Addenda) "Reference Guide Correction" "100000761" "2011-02-02" "Commercial Interiors" "None" "None" "Green Interior Design and Construction, 2009 edition" "375" "4. Implementation" "Add the following paragraph after the second paragraph: \n\nIndividual comfort plug-in devices are acceptable for meeting the intent of this credit provided they are included in EA Prerequisite 2: Minimum Energy Performance and the proposed design model but not in the baseline model for EA Credit 1.3: Optimize Energy Performance, and EA Credit 1.4: Optimize Energy Performance--Equipment and Appliances as appropriate." "Reference Guide Correction" "100001118" "2011-11-01" "New Construction, Schools - New Construction, Core and Shell, Healthcare, Retail - New Construction, Commercial Interiors, Retail - Commercial Interiors" "None" "None" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010 $ Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011" "BD+C RG: 532
ID+C RG: 378" "Definitions" "In alphabetical order, add the following definition for multi-occupant spaces, ""Multi-Occupant Spaces are places of egress, congregation, or where occupants pursue overlapping or collaborative tasks. Multi occupant spaces may be regularly or non-regularly occupied spaces.""\n" "Reference Guide Correction" "100001123" "2011-11-01" "New Construction, Schools - New Construction, Core and Shell, Healthcare, Retail - New Construction, Commercial Interiors, Retail - Commercial Interiors" "None" "None" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010 $ Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011" "BD+C RG: 532
ID+C RG: 378" "Definitions" "Revise the definition for individual occupant spaces to be, ""In individual occupant spaces, occupants perform distinct tasks from one another. Such spaces may be contained within multi-occupant spaces and should be treated separately where possible. Individual occupant spaces may be regularly or non-regularly occupied spaces.""\n" "Global ACP" "100001564" "2012-10-01" "Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011" "CI RS 55" "Requirements" "Delete the final sentence under requirements." "Global ACP" "100001563" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 55, Retail CI RS 52" "Requirements" "Add a new paragraph below the first paragraph that reads: ""Conditions for thermal comfort are described in IEQ credit 7.1: Thermal Comfort-Design and include the primary factors of air temperature, radiant temperature, air speed and humidity.""" "LEED Interpretation" "1770" "2007-05-07" "New Construction, Existing Buildings, Commercial Interiors, Core and Shell, Schools - New Construction, Retail - New Construction, Retail - Commercial Interiors, Healthcare" "The project team is providing individual floor air valves each with variable duration (open / close) primary air dampers and multi-position diffusers for occupant comfort conditioning as part of an under floor air distribution system. Individual floor air valves will be provided for a minimum of 50% of the building occupants. The variable duration (open/close) primary air dampers in the floor air valves will be controlled using thermostats. Multiple air valves will be connected to one thermostat, such that there will not be one thermostat for 50% of the occupants. However, all of the local floor air valves include multi-position adjustable floor diffusers which are integral to each floor air valve. At a minimum, 50% of the occupants will have control over the primary air flow direction out of the local floor air valve in their space (comfort zone) by adjusting the multi-position local floor diffuser air outlet. Changing the direction of the air flow inherently changes the speed of the airflow in a given direction. LEED NC v.2.2, First Edition, Reference Guide, p361, indicates: Conditions for Thermal Comfort per ASHRAE Standard 55-2004 include the following as primary factors: air temperature, radiant temperature, air speed, and humidity. The Reference guide also states that, ""Comfort System control, for the purposes of this credit, is defined as the provision of control over at least one of these primary factors in the occupant\'s local environment"" and that ""Individual adjustments may involve individual thermostat controls, local diffusers at floor, desk or overhead levels, or control of individual radiant panels, and energy system design."" This CIR is to confirm that providing air valves, with multi position diffusers, that allow more than 50% of the occupants to change the direction of airflow out of their floor diffuser (which changes the speed in that direction) will satisfy the LEED credit requirement for thermal comfort." "The applicant is asking whether multi position diffusers that allow changes in direction of airflow satisfy the requirements for individual comfort control for EQc6.2. The applicant is suggesting that changing the direction of airflow inherently changes the speed of the airflow in a given direction, meeting credit compliance by providing control of air speed. Simply changing the direction of airflow in one\'s workspace does not adequately meet the credit intent to provide individual comfort controls. Individual diffusers must have the ability to regulate the speed of the air leaving the diffuser, not simply the direction of airflow. Applicable Internationally." "None" "None" "X"