Entry Type ID Date Applicable Rating System Primary Credit Inquiry (LIs) Ruling (LIs) Related Addenda/LIs Related Resources Campus Applicable Internationally Applicable Country Applicability Reference Guide (Addenda) Page (Addenda) Location (Addenda) Description of Change (Addenda) "Rating System Correction, Reference Guide Correction" "100000424" "2010-04-14" "New Construction, Core and Shell" "None" "None" "Green Building Design and Construction, 2009 edition" " NC Rating System: 69, CS Rating System: 67, Reference Guide: 487" "OPTION 1" "Remove the fifth bulleted item" "Rating System Correction, Reference Guide Correction" "100000143" "2010-04-14" "Commercial Interiors" "None" "None" "Green Interior Design and Construction, 2009 edition" " Rating System: 49, Reference Guide:343" "OPTION 1" "Remove the fifth bulleted item" "Rating System Correction, Reference Guide Correction" "100000423" "2010-04-14" "New Construction, Core and Shell" "10267" "None" "Green Building Design and Construction, 2009 edition" " NC Rating System: 69, CS Rating System: 67, Reference Guide: 487" "OPTION 1" "Replace the text of the fourth bulleted item with the following text:\n\nAll hard surface flooring must meet the requirements of the FloorScore?\nstandard (current as of the date of this rating system, or more stringent\nversion) as shown with testing by an independent third-party. Mineralbased\nfinish flooring products such as tile, masonry, terrazzo, and cut\nstone without integral organic-based coatings and sealants and\nunfinished/untreated solid wood flooring qualify for credit without any IAQ\ntesting requirements. However, associated site-applied adhesives, grouts,\nfinishes and sealers must be compliant for a mineral-based or\nunfinished/untreated solid wood flooring system to qualify for credit." "Rating System Correction, Reference Guide Correction" "100000425" "2010-04-14" "New Construction, Schools - New Construction, Core and Shell" "10267" "None" "Green Building Design and Construction, 2009 edition" " NC Rating System: 70, Schools Rating System: 69, CS Rating System: 69, Reference Guide: 488" "OPTION 2" "At the end of the paragraph, add the following text:\n\nMineral-based finish flooring products such as tile, masonry, terrazzo, and\ncut stone without integral organic-based coatings and sealants and\nunfinished/untreated solid wood flooring qualify for credit without any IAQ\ntesting requirements. However, associated site-applied adhesives, grouts,\nfinishes and sealers must be compliant for a mineral-based or\nunfinished/untreated solid wood flooring system to qualify for credit." "Rating System Correction, Reference Guide Correction" "100000142" "2010-04-14" "Commercial Interiors" "10267" "None" "Green Interior Design and Construction, 2009 edition" " Rating System: 49, Reference Guide:343" "OPTION 1" "Replace the text of the fourth bulleted item with the following:\n\nAll hard surface flooring must meet the requirements of the FloorScore?\nstandard (current as of the date of this rating system, or more stringent\nversion) as shown with testing by an independent third-party. Mineral-based\nfinish flooring products such as tile, masonry, terrazzo, and cut\nstone without integral organic-based coatings and sealants and\nunfinished/untreated solid wood flooring qualify for credit without any IAQ\ntesting requirements. However, associated site-applied adhesives,\ngrouts, finishes and sealers must be compliant for a mineral-based or\nunfinished/untreated solid wood flooring system to qualify for credit." "Rating System Correction, Reference Guide Correction" "100000144" "2010-04-14" "Commercial Interiors" "10267" "None" "Green Interior Design and Construction, 2009 edition" " Rating System: 49, Reference Guide:343" "OPTION 2" "At the end of the paragraph, add the following text:\n\nMineral-based finish flooring products such as tile, masonry, terrazzo,\nand cut stone without integral organic-based coatings and sealants and\nunfinished/untreated solid wood flooring qualify for credit without any IAQ\ntesting requirements. However, associated site-applied adhesives,\ngrouts, finishes and sealers must be compliant for a mineral-based or\nunfinished/untreated solid wood flooring system to qualify for credit." "Reference Guide Correction" "100000764" "2011-02-02" "New Construction, Schools - New Construction, Core and Shell" "None" "None" "Green Building Design and Construction, 2009 edition" "492" "9. Exemplary Performance" "Replace text with the following:\n\nNC & Schools\nThis credit is not eligible for exemplary performance under the Innovation and Design section.\n\nCS\nProjects that require and enforce tenants to meet the requirements in IEQ Credit 4 (4.1, 4.2, 4.3, and 4.4) throughout the tenant space are eligible for exemplary performance under the Innovation in Design section." "Global ACP" "100001549" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "The first bullet should read: ""All carpet installed in the building interior must meet one of the following requirements:""" "Global ACP" "100001556" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "Add three new bullets below the fourth original bullet." "Global ACP" "100001557" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "The first new bullet should read: ""Meet the requirements of the Floor Score2 standard (current as of the date of this rating system, or more stringent version) as shown with testing by an independent third-party.""" "Global ACP" "100001550" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "Add three bullets, indented, below the first bullet" "Global ACP" "100001558" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "The second new bullet should read: ""Demonstrate maximum VOC concentrations less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice."" " "Global ACP" "100001559" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "The third new bullet should read: ""Maximum VOC concentrations meet the California requirements specified above based on the following: o California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point o Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than " "Global ACP" "100001560" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "Add a new paragraph after the third new bullet that reads: ""If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7."" " "Global ACP" "100001561" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "Below the final bullet, add the following: "" For carpet adhesive, concrete, wood, bamboo and cork floor finishes, and tile setting adhesives, compliance can be demonstrated with test results of:\n  Total volatiles fraction, based on one of the following, provided that water and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168:\n o ASTM D2369\n o EPA method 24\n o ISO 11890 part 1\n  Total volatile organic compounds fraction, based on one of the following, provided that all VOCs with a boiling point up to 280°C (536°F) are included, and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168.\n o ASTM D6886\n o ISO 11890 part 2”" "Global ACP" "100001551" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "The first new bullet should read: ""Meets the testing and product requirements of the Carpet and Rug Institute Green Label Plus program.""" "Global ACP" "100001552" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "The second new bullet should read: ""Maximum VOC concentrations are less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice. The additional VOC concentration limits listed in Section 9.1a must also be met.""" "Global ACP" "100001553" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "The third new bullet should read: ""Maximum VOC concentrations meet the California requirements specified above based on the following: o California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point o Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than " "Global ACP" "100001554" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "Add a paragraph below the third new bullet that reads: ""If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7."" " "Global ACP" "100001555" "2012-10-01" "Commercial Interiors, Retail - Commercial Interiors" "None" "None" "X" "Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011 $ Retail Supplement to Green Interior Design and Construction, 2009 edition" "CI RS 49, Retail CI RS 45" "Option 1" "The fourth original bullet should read ""All hard surface flooring installed in the building interior must meet one of the following requirements:""" "Global ACP" "100001720" "2012-10-01" "New Construction, Core and Shell, Schools - New Construction, Commercial Interiors" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010 $ Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011" "BD+C RG: 493
ID+C RG: 347" "Definitions, volatile organic compounds (VOCs)" "Replace the definition of ""volatile organic compounds (VOC's)"" with ""a carbon compound that vaporizes (becomes a gas) at normal room temperatures. VOCs contribute to air pollution directly and through atmospheric photochemical reactions (excluding carbon monoxide, carbon dioxide, carbonic acid, metallic carbides and carbonates, and ammonium carbonate) to produce secondary air pollutants, principally ozone and peroxyacetyl nitrate.""" "Global ACP" "100001721" "2012-10-01" "New Construction, Core and Shell, Schools - New Construction, Commercial Interiors, Existing Buildings" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010 $ Green Interior Design and Construction, 2009 edition $ Green Interior Design and Construction, 2009 edition, updated June 2011" "BD+C RG: 489
ID+C RG: 344
BO+M: 272
" "3. Summary of Referenced Standards" "Under ""Carpet and Rug Institute (RCI) Green Label Plus Testing Program, replace ""http://www.carpet-rug.com"" with ""http://www.carpet-rug.org.""" "Global ACP" "100001313" "2012-07-06" "New Construction, Core and Shell" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The first bullet should read: ""All carpet installed in the building interior must meet one of the following requirements:""" "Global ACP" "100001321" "2012-07-06" "New Construction, Core and Shell" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add a new paragraph after the bullets that reads: ""If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7.""" "Global ACP" "100001324" "2012-07-06" "New Construction, Core and Shell" "100001323" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The first new bullet should read: ""Meet the requirements of the FloorScore standard (current as of the date of this rating system, or more stringent version) as shown with testing by an independent third-party.""" "Global ACP" "100001328" "2012-07-06" "New Construction, Core and Shell" "100001327" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The first indented bullet should read: ""California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point""" "Global ACP" "100001329" "2012-07-06" "New Construction, Core and Shell" "100001327" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The second indented bullet should read: ""Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than 1/2 of the concentration limit specified above because the emission may not have peaked at the measured time points.""" "Global ACP" "100001330" "2012-07-06" "New Construction, Core and Shell" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add a new paragraph after the bullets that reads: ""If a European testing method (AgBB/DIBt GUT, EMICODE, Blue Angel) had used parameters for calculating test results different from those specified in the referenced California method, then the European test results for carpets or floorings need to be converted into California air concentrations by multiplication with 0.7.""" "Global ACP" "100001331" "2012-07-06" "New Construction, Core and Shell" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add a new bullet at the end of Option 1 that reads: ""For carpet adhesive, concrete, wood, bamboo and cork floor finishes, and tile setting adhesives, compliance can be demonstrated with test results of:""" "Global ACP" "100001332" "2012-07-06" "New Construction, Core and Shell" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add a new indented bullet after the last bullet that reads: ""Total volatiles fraction, based on one of the following, provided that water and exempt compounds are subtracted from total volatiles test results and the mass VOC content is calculated consistent with SCAQMD Rule 1113 and Rule 1168:""" "Global ACP" "100001333" "2012-07-06" "New Construction, Core and Shell" "100001334, 100001335, 100001336" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add three new bullets, indented further, after the new indented bullet:" "Global ACP" "100001334" "2012-07-06" "New Construction, Core and Shell" "100001333" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The first new indented bullet should read: ""ASTM D2369""" "Global ACP" "100001335" "2012-07-06" "New Construction, Core and Shell" "100001333" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The second new indented bullet should read: ""EPA method 24""" "Global ACP" "100001336" "2012-07-06" "New Construction, Core and Shell" "100001333" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The third new indented bullet should read: ""ISO 11890 part 1""" "Global ACP" "100001337" "2012-07-06" "New Construction, Core and Shell" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add a new bullet after the three options, indented to the same level as the bullet for ""Total volatiles fraction"" that reads: ""Total volatile organic compounds fraction, based on one of the following, provided that all VOCs with a boiling point up to 280" "Global ACP" "100001338" "2012-07-06" "New Construction, Core and Shell" "100001339, 100001340" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add two new bullets, indented further, after the new indented bullet:" "Global ACP" "100001339" "2012-07-06" "New Construction, Core and Shell" "100001338" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The first new indented bullet should read: ""ASTM D6886""" "Global ACP" "100001340" "2012-07-06" "New Construction, Core and Shell" "100001338" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The second new indented bullet should read: ""ISO 11890 part 2""" "Global ACP" "100001341" "2012-07-06" "New Construction, Core and Shell" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Requirements" "Delete the Alternative Compliance Path for Projects Outside the U.S." "Global ACP" "100001314" "2012-07-06" "New Construction, Core and Shell" "100001315, 100001316, 100001317" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Under the first bullet, add three new bullets, indented:" "Global ACP" "100001315" "2012-07-06" "New Construction, Core and Shell" "100001314" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The first new bullet should read: ""Meets the testing and product requirements of the Carpet and Rug Institute Green Label Plus""" "Global ACP" "100001316" "2012-07-06" "New Construction, Core and Shell" "100001314" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The second new bullet should read: ""Maximum VOC concentrations are less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice. The additional VOC concentration limits listed in Section 9.1a must also be met.""" "Global ACP" "100001317" "2012-07-06" "New Construction, Core and Shell" "100001314" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The third new bullet should read: ""Maximum VOC concentrations meet the California requirements specified above based on the following:""" "Global ACP" "100001318" "2012-07-06" "New Construction, Core and Shell" "100001319, 100001320" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add 2 bullets below the third new bullet, indented further:" "Global ACP" "100001319" "2012-07-06" "New Construction, Core and Shell" "100001318" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The first indented bullet should read: ""California Department of Public Health (CDPH) Standard Method V1.1-2010 using test results obtained at the 14 day time point""" "Global ACP" "100001320" "2012-07-06" "New Construction, Core and Shell" "100001318" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The second indented bullet should read: ""Projects outside the U.S. may use the German AgBB/DIBt testing method and all testing methods based on AgBB/DIBt method (GUT, EMICODE, Blue Angel) using test results obtained at the 3 day or 7 day or 14 day time point. For caprolactam, if test results obtained at the 3 day or 7 day time point is used, the emission concentration must be less than 1/2 of the concentration limit specified above because the emission may not have peaked at the measured time points.""" "Global ACP" "100001322" "2012-07-06" "New Construction, Core and Shell" "None" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The fourth original bullet should read: ""All hard surface flooring installed in the building interior must meet one of the following requirements:""" "Global ACP" "100001323" "2012-07-06" "New Construction, Core and Shell" "100001324, 100001325, 100001326" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Under the fourth original bullet, add three new bullets, indented:" "Global ACP" "100001325" "2012-07-06" "New Construction, Core and Shell" "100001323" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The second new bullet should read: ""Demonstrate maximum VOC concentrations less than or equal to those specified in the California Department of Health Services Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers, including 2004 Addenda, using the office scenario as defined in Table 7.5 within the practice.""" "Global ACP" "100001326" "2012-07-06" "New Construction, Core and Shell" "100001323" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "The third new bullet should read: ""Maximum VOC concentrations meet the California requirements specified above based on the following:""" "Global ACP" "100001327" "2012-07-06" "New Construction, Core and Shell" "100001328, 100001329" "None" "X" "Green Building Design and Construction, 2009 edition $ Green Building Design and Construction, 2009 Edition, updated June 2010" "NC RS: 81, CS RS: 79" "Option 1" "Add 2 bullets below the third new bullet, indented further:" "LEED Interpretation" "10267" "2013-01-01" "New Construction, Commercial Interiors, Core and Shell, Schools - New Construction, Retail - New Construction, Retail - Commercial Interiors, Healthcare" "According to footnote 1 on the IEQc4.3 Form, ""Mineral-based finish flooring products such as tile, masonry, terrazzo, and cut stone without any integral organic-based coatings and sealants and unfinished/untreated solid wood flooring qualify for credit without any IAQ testing requirements."" Is it necessary to list them as a material on the form since there is no way to indicate that it is exempt from testing?" "The project team is asking whether mineral-based finish flooring products (without any integral organic-based coatings and sealants) and unfinished/untreated solid wood flooring need to be included on the LEED IEQc4.3 (Low-Emitting Materials - Flooring Systems) Credit Form. Yes, the project team should mark the form to indicate an Alternative Compliance Path. The required narrative for the Alternative Compliance Path must include a statement that the project is applying the April 14, 2010 addenda, as well as the manufacturer and specific product description of the product claiming the exemption. Manufacturer documentation for each product claiming an exemption is NOT required. Applicable Internationally." "100000423, 100000425, 100000142, 100000144" "None" "X"