Entry Type ID Date Applicable Rating System Primary Credit Inquiry (LIs) Ruling (LIs) Related Addenda/LIs Related Resources Campus Applicable Internationally Applicable Country Applicability Reference Guide (Addenda) Page (Addenda) Location (Addenda) Description of Change (Addenda) "LEED Interpretation" "10406" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors, Existing Buildings, Schools - Existing Buildings, Retail - Existing Buildings, Data centers - Existing Buildings, Hospitality - Existing Buildings, Warehouse and distribution centers - Existing Buildings" "MRc5 - Building product disclosure and optimization - material ingredients" "Can Cradle to Cradle certified products use the Material Health score to meet the credit requirements for Option 2 in the Material Ingredients credit instead of the overall score for the product (including energy, water, etc.)? " "Yes, products that have received a full C2C certification may use the score for the material health category to document Option 2 of the Material Ingredients credit. The value for the material health score follows the same levels as a full product certification (C2C v2 Gold valued at 100%, platinum at 150%; C2C v3 Silver – 100%, Gold and Platinum - 150%). " "None" "None" "X" "Rating System Correction, Reference Guide Correction" "100001834" "2014-07-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors, Existing Buildings, Schools - Existing Buildings, Retail - Existing Buildings, Data centers - Existing Buildings, Hospitality - Existing Buildings, Warehouse and distribution centers - Existing Buildings" "MRc4 - Building product disclosure and optimization - sourcing of raw materials" "None" "None" "X" "LEED v4 Reference Guide for Building Design and Construction, LEED v4 Reference Guide for Interior Design and Construction, LEED Reference Guide for Operation and Maintnance" "RS:LEED BD+C:95, RG:LEED BD+C:526, RS:LEED ID+C:50, LEED ID+C: 264; RS:LEED O+M:63, RG:LEED O+M:355" "LEED BD+C Requirements, Option 2; LEED ID+C Requirements, Option 2; LEED O+M Requirements, Option 1" "Change first sentence in last paragraph to read ""For credit achievement calculation, products sourced (extracted, manufactured, and purchased) within 100 miles (160 km) of the project site are valued at...""" "Reference Guide Correction" "100001928" "2014-10-01" "Existing Buildings, Schools - Existing Buildings, Retail - Existing Buildings, Data centers - Existing Buildings, Hospitality - Existing Buildings, Warehouse and distribution centers - Existing Buildings" "MRc5 - Purchasing - facility maintenance and renovation" "None" "None" "X" "367" "Examples, Example 1" "Table 1. Example calculation for multiple criteria\n In 4th column labeled ""Contributing value"" change the row for ""Extended producer responsibility"" from ""2,000"" to "".5 X $2,000 = $1,000"", change the total from ""$5,200"" to ""4,200"". \n In the 2nd column labeled” Criterion” change the row for “Recycled content (60%) to “Postconsumer recycled content.” In the same column, change the row for “Cradle-to-Cradle v2 certified” to “Cradle-to-Cradle v2 Gold”\n Also, under the table change the instance of the value ""$5,200"" to ""4,200""." "Form Update" "5000011" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors, Existing Buildings, Schools - Existing Buildings, Retail - Existing Buildings, Data centers - Existing Buildings, Hospitality - Existing Buildings, Warehouse and distribution centers - Existing Buildings" "MRc3 - Building product disclosure and optimization - sourcing of raw materials" "None" "BPDO Calculator, Purchasing Calculator, Furniture and Medical Furnishings Calculator" "X" "Revised location valuation factor calculations to specify that the entire product meets local criteria." "Reference Guide Correction" "100001925" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors, Existing Buildings, Schools - Existing Buildings, Retail - Existing Buildings, Data centers - Existing Buildings, Hospitality - Existing Buildings, Warehouse and distribution centers - Existing Buildings" "MRc5 - Building product disclosure and optimization - material ingredients" "None" "None" "X" "BD+C: 551; ID+C: 289; O+M:369" "Further Explanation, International Tips" "In the last sentence of the third paragraph, replace ""also"" with ""not"" so that the sentence reads: ""Projects in the U.S. may not use this alternative compliance path."""