Entry Type ID Date Applicable Rating System Primary Credit Inquiry (LIs) Ruling (LIs) Related Addenda/LIs Related Resources Campus Applicable Internationally Applicable Country Applicability Reference Guide (Addenda) Page (Addenda) Location (Addenda) Description of Change (Addenda) "Rating System Correction, Reference Guide Correction" "100001842" "2014-07-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors" "EQ114 - Indoor air quality assessment" "None" "None" "X" "X" "LEED v4 Reference Guide for Building Design and Construction, LEED v4 Reference Guide for Interior Design and Construction" "RS:LEED BD+C:124,RG:LEED BD+C:685-687,690-692; RS:LEED ID+C:63, RG:LEED ID+C:365-367,370-372" "Requiermants; Behind the Intent; Further Explanations- Calculations" "Modify the SI unit conversions:\n Path 1, change 4 267 140 liters per second of outdoor air per square meter' to '4 267 140 liters of outdoor air per square meter'. \n Path 2, change '1 066 260 liters per second of outdoor air per square meter' to '1 066 260 liters of outdoor air per square meter'. \n Path 2, change ‘1.5 liters of outside air per second per square meter’ to ‘1.5 liters per second per square meter of outdoor air’.\n Path 2, change ‘4 270 cubic meters of outdoor air per square meter’ to ‘4 270 liters of outdoor air per square meter’.\n\n Behind the intent, in third paragraph, add SI for airflow rate so reads ‘0.7 cubic feet per minute per square foot (3.55 liters per second per square meter)’\n\n Behind the intent image/calculation change ‘4 294 080 lps’ to ‘4 294 080 l’\n\n Equation 1, change ‘14,000 cfm’ to ‘14,000 ft3/ft2’ and ‘4 267 140 lps’ to ‘4 267 140 l/m2’\n Equation 2, change ‘3,500 cfm of outdoor air’ to ‘3,500 ft3/ft2’ and ‘1 066 260 lps’ to 1 066 260 l/m2’\n Equation 3, change ’10,500 cfm’ to ’10,500 ft3/ft2’ and 3 200 880 lps’ to ‘3 200 880 l/m2’\n Equation ,4 change ‘14,000 cfm’ to ‘14,000 ft3/ft2’ and ‘4 267 140 lps’ to ‘4 267 140 l/m2’ \n\n Table 2, change column header to Total Outdoor Air Required (ft3/ft2)\n Table 3, change column header to Total Outdoor Air Required (l/m2)\n Table 4, change column header to ‘Total outdoor air required before occupancy (cfm/ft2)' and column header to ‘Total outdoor air required to complete flush-out (ft3/ft2), and modify volume of air required to complete flush out (ft3) if applicable.\n Table 5, change column header from ‘Total outdoor air required before occupancy (l/m2)' and column header to ‘Total outdoor air required to complete flush-out (l/m2).\n" "Form Update" "5000004" "2014-07-01" "New Construction, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors" "EQc4 - Indoor air quality assessment" "None" "None" "X" "X" "Under Option 1, Path 2, removed checkbox, ""New filtration media were installed before the flush-out began."" "