Entry Type ID Date Applicable Rating System Primary Credit Inquiry (LIs) Ruling (LIs) Related Addenda/LIs Related Resources Campus Applicable Internationally Applicable Country Applicability Reference Guide (Addenda) Page (Addenda) Location (Addenda) Description of Change (Addenda) "Reference Guide Correction" "100001831" "2014-07-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors" "None" "None" "X" "BD+C: 300; ID+C: 106" "Step-By-Step Guidance, Step 2" "Remove ""seawater"" from list of untreated water sources ineligible for this credit.\n Add ""treated seawater"" to the list of acceptable alternative water sources, behind stormwater. " "Reference Guide Correction" "100001913" "2014-10-01" "Schools - New Construction, Retail - New Construction, Healthcare, Hospitality - New Construction" "None" "None" "298" "Requirements, Appliance and Process Water" "In Table 3, under food waste disposer, change 43.8 lpm to 3.8 lpm" "Reference Guide Correction" "100001914" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors, Existing Buildings, Schools - Existing Buildings, Retail - Existing Buildings, Data centers - Existing Buildings, Hospitality - Existing Buildings, Warehouse and distribution centers - Existing Buildings" "None" "International Water Labeling Programs" "X" "BD+C 279; ID+C:99; O+M: 145, 170" "Further Explanation, International Tips" "Replace ""Projects in unlisted countries must comply with the 20%-below-baseline requirement but have no additional performance requirements"" with: ""Project outside the U.S. must meet WaterSense flush and flow rates.""\nn Change to Guidance document:\n ""Projects in countries listed in the WaterSense Equivalencies section of the International Water Labeling Programs document must select fixtures with the designated label in place of the WaterSense requirement.\n\n Countries without a listed labeling program must meet the following flush and flow requirements: (Table 6 minus private lav and kitchen sinks) \n\n *Tank type toilets only. Flushometer toilets do not have an equivalent requirement for WaterSense."" " "Reference Guide Correction" "100001912" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction" "None" "None" "X" "301" "Further Explanation, Project Type Variations" "Add Additions to Project Type Variations – \n\n Additions\n For credit compliance, include in the credit documentation all plumbing fixtures necessary to meet the occupants’ needs whether they will be installed as part of the project’s scope of work or not. Include at a minimum all necessary restroom fixtures (toilets, urinals, and lavatories) to meet the project occupants’ needs, and showers when seeking LT Credit Bicycle Facilities. The WaterSense label requirement does not apply to fixtures that are outside of the scope of the LEED project. " "Form Update" "5000025" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors" "None" "None" "X" "X" "For CS projects only, added tenant lease agreement upload and narrative describing future tenant plumbing fixtures to WE Credit Indoor Water Use Reduction section. Throughout form, added instructional notes clarifying when field values should be based on developer-installed fixtures versus future tenant plumbing fixtures. "