Entry Type ID Date Applicable Rating System Primary Credit Inquiry (LIs) Ruling (LIs) Related Addenda/LIs Related Resources Campus Applicable Internationally Applicable Country Applicability Reference Guide (Addenda) Page (Addenda) Location (Addenda) Description of Change (Addenda) "Rating System Correction, Reference Guide Correction" "100001834" "2014-07-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors, Existing Buildings, Schools - Existing Buildings, Retail - Existing Buildings, Data centers - Existing Buildings, Hospitality - Existing Buildings, Warehouse and distribution centers - Existing Buildings" "MRc4 - Building product disclosure and optimization - sourcing of raw materials" "None" "None" "X" "LEED v4 Reference Guide for Building Design and Construction, LEED v4 Reference Guide for Interior Design and Construction, LEED Reference Guide for Operation and Maintnance" "RS:LEED BD+C:95, RG:LEED BD+C:526, RS:LEED ID+C:50, LEED ID+C: 264; RS:LEED O+M:63, RG:LEED O+M:355" "LEED BD+C Requirements, Option 2; LEED ID+C Requirements, Option 2; LEED O+M Requirements, Option 1" "Change first sentence in last paragraph to read ""For credit achievement calculation, products sourced (extracted, manufactured, and purchased) within 100 miles (160 km) of the project site are valued at...""" "LEED Interpretation" "10409" "2015-01-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors" "MRc3 - Building product disclosure and optimization - environmental product declarations" "Can equipment and machinery in CSI divisions 11, 21-28 and other specialty divisions, including special equipment such as elevators, escalators, process equipment, and fire suppression systems contribute towards the 20 minimum number of products required in Option 1 of Building Product Disclosure and Optimization – Environmental Product Declarations, Building Product Disclosure and Optimization – Sourcing of Raw Materials, and of Building Product Disclosure and Optimization – Material Ingredients?" "Yes, these products may contribute towards Option 1 of Building Product Disclosure and Optimization – Environmental Product Declarations, Building Product Disclosure and Optimization – Sourcing of Raw Materials, and of Building Product Disclosure and Optimization – Material Ingredients. Note that if these products are included in Option 1 of a credit, they are not required to be included in Option 2." "None" "None" "X" "Reference Guide Correction" "100001921" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors" "MRc3 - Building product disclosure and optimization - environmental product declarations" "None" "None" "X" "BD+C 469; ID+C 219" "Overview, Qualifying Products and Exclusions" "In the 3rd paragraph for BD+C and 2nd paragraph for ID+C replace the 4th-7th sentences with the following: ""If optional products or materials are included in cost-based credit calculations, such as Option 2 under each Building Product Disclosure and Optimization credits, they must be included consistently across all cost-based credit calculations. Additionally, if optional products and materials are included in product based calculations, such as Option 1 under each Building Product Disclosure and Optimization credits, they are not required to be included in cost-based credit calculations. However, unlike furniture, if some of these products are included in credit calculations, not all products of that type must be included.""" "Reference Guide Correction" "100001922" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors" "MRc3 - Building product disclosure and optimization - environmental product declarations" "None" "None" "X" "BD+C 472; ID+C 222" "Overview, Determining Material Contributions of an Assembly" "In Table 1. Example Calculation for $500 office chair, the row “Wheels” in the column “Percentage of component meeting sustainability criteria” replace ""5% with ""10%"" so the cell reads “10% postconsumer recycled content”" "Form Update" "5000011" "2014-10-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors, Existing Buildings, Schools - Existing Buildings, Retail - Existing Buildings, Data centers - Existing Buildings, Hospitality - Existing Buildings, Warehouse and distribution centers - Existing Buildings" "MRc3 - Building product disclosure and optimization - sourcing of raw materials" "None" "BPDO Calculator, Purchasing Calculator, Furniture and Medical Furnishings Calculator" "X" "Revised location valuation factor calculations to specify that the entire product meets local criteria." "Form Update" "5000026" "2015-04-01" "New Construction, Core and Shell, Schools - New Construction, Retail - New Construction, Healthcare, Data centers - New Construction, Hospitality - New Construction, Warehouse and distribution centers - New Construction, Commercial Interiors, Retail - Commercial Interiors, Hospitality - Commercial Interiors" "MR114 - Building product disclosure and optimization - sourcing of raw materials" "None" "BPDO Calculator" "Revisions to the 30% cap on structure and enclosure materials."