Acoustic performance

Possible 2 points

Intent

To provide workspaces and classrooms that promote occupants’ well-being, productivity, and communications through effective acoustic design.

Requirements

For all occupied spaces, meet the following requirements, as applicable, for HVAC background noise, sound isolation, reverberation time, and sound reinforcement and masking.

HVAC Background Noise

Achieve maximum background noise levels from heating, ventilating, and air conditioning (HVAC) systems per 2011 ASHRAE Handbook, HVAC Applications, Chapter 48, Table 1; AHRI Standard 885-2008, Table 15; or a local equivalent. Calculate or measure sound levels.

For measurements, use a sound level meter that conforms to ANSI S1.4 for type 1 (precision) or type 2 (general purpose) sound measurement instrumentation, or a local equivalent.

Comply with design criteria for HVAC noise levels resulting from the sound transmission paths listed in ASHRAE 2011 Applications Handbook, Table 6; or a local equivalent.

Sound Isolation

Meet the composite sound transmission class (STCC) ratings listed in Table 1, or local building code, whichever is more stringent.

Table 1. Maximum composite sound transmission class ratings for adjacent spaces

Adjacency combinations STCC
Residence (within a multifamily residence), hotel or motel room Residence, hotel or motel room 55
Residence, hotel or motel room Common hallway, stairway 50
Residence, hotel or motel room Retail 60
Retail Retail 50
Standard office Standard office 45
Executive office Executive office 50
Conference room Conference room 50
Office, conference room Hallway, stairway 50
Mechanical equipment room Occupied area 60

Reverberation Time

Meet the reverberation time requirements in Table 3 (adapted from Table 9.1 in the Performance Measurement Protocols for Commercial Buildings1).

Table 3. Reverberation time requirements
Room type Application T60 (sec), at 500 Hz, 1000 Hz, and 2000 Hz
Apartment and condominium < 0.6
Hotel/motel Individual room or suite < 0.6
Meeting or banquet room < 0.8
Office building Executive or private office < 0.6
Conference room < 0.6
Teleconference room < 0.6
Open-plan office without sound masking < 0.8
Open-plan office with sound masking 0.8
Courtroom Unamplified speech < 0.7
Amplified speech < 1.0
Performing arts space Drama theaters, concert and recital halls Varies by application
Laboratories Testing or research with minimal speech communication < 1.0
Extensive phone use and speech communication < 0.6
Church, mosque, synagogue General assembly with critical music program Varies by application
Library   < 1.0
Indoor stadium, gymnasium Gymnasium and natatorium < 2.0
Large-capacity space with speech amplification < 1.5
Classroom < 0.6

Sound Reinforcement and Masking Systems

Sound Reinforcement
For all large conference rooms and auditoriums seating more than 50 persons, evaluate whether sound reinforcement and AV playback capabilities are needed.

If needed, the sound reinforcement systems must meet the following criteria:

  • Achieve a speech transmission index (STI) of at least 0.60 or common intelligibility scale (CIS) rating of at least 0.77 at representative points within the area of coverage to provide acceptable intelligibility.
  • Have a minimum sound level of 70 dBA and must
  • Maintain sound-level coverage within +/–3 dB at the 2000 Hz octave band throughout the space.

Masking Systems
For projects that use masking systems, the design levels must not exceed 48 dBA. Ensure that loudspeaker coverage provides uniformity of +/–2 dBA and that speech spectra are effectively masked.


1 Adapted from ASHRAE (2007d), ASA (2008), ANSI (2002), and CEN (2007)

Join LEEDuser

Ask questions, share tips, and get notified of new forum posts by joining LEEDuser, a tool developed by BuildingGreen and supported by USGBC!

  • Share on Twitter
  • Share on Facebook
  • Share on LinkedIn
  • Print to PDF
Sample forms
Version: v01
Active Form
View all sample forms

0 commentsLeave a comment

Leave a comment Don't have an account? Create one

You must be signed in to leave a comment.