LEED O+M: Existing Buildings v2 - LEED 2.0

Dept. of Treasury - Main Building

1500 Pennsylvania Avenue NW
Washington, DC 20220
United States
Map

LEED Gold 2011

LEED Scorecard

Gold 48/85

  • SSc1

    Plan for green site and building exterior management 2 / 2
  • SSc2

    High development density building and area 1 / 1
  • SSc3.1

    Alternative transportation - public transportation access 1 / 1
  • SSc3.2

    Alternative transportation - bicycle storage & changing rooms 1 / 1
  • SSc3.3

    Alternative transportation - alternative fuel vehicles 0 / 1
  • SSc3.4

    Alternative transportation - car pooling and telecommuting 0 / 1
  • SSc4

    Reduced site disturbance - protect or restore open space 0 / 2
  • SSc5

    Stormwater management - rate and quantity reduction 0 / 2
  • SSc6.1

    Heat island reduction - non-roof 0 / 1
  • SSc6.2

    Heat island reduction - roof 0 / 1
  • SSc7

    Light pollution reduction 0 / 1
  • WEc1

    Water efficient landscaping - reduce water use 1 / 2
  • WEc2

    Innovative wastewater technologies 0 / 1
  • WEc3.1

    Water use reduction 1 / 1
  • WEc3.2

    Water use reduction 1 / 1
  • EAc1

    Optimize energy performance 0 / 10
  • EAc2

    On-site and off-site renewable energy 4 / 4
  • EAc3.1

    Building operations and maintenance - staff education 0 / 1
  • EAc3.2

    Building operations and maintenance - building systems maintenance 1 / 1
  • EAc3.3

    Building operations and maintenance - building systems monitoring 0 / 1
  • EAc4

    Additional ozone protection 0 / 1
  • EAc5.1

    Performance measurement - enhanced metering 1 / 1
  • EAc5.2

    Performance measurement - enhanced metering 0 / 1
  • EAc5.3

    Performance measurement - enhanced metering 0 / 1
  • EAc5.4

    Performance measurement - emission reduction reporting 1 / 1
  • EAc6

    Documenting sustainable building cost impacts 1 / 1
  • MRc1.1

    Construction, demolition and renovation waste management 1 / 1
  • MRc1.2

    Construction, demolition and renovation waste management 1 / 1
  • MRc2.1

    Optimize use of alternative materials 1 / 1
  • MRc2.2

    Optimize use of alternative materials 1 / 1
  • MRc2.3

    Optimize use of alternative materials 1 / 1
  • MRc2.4

    Optimize use of alternative materials 1 / 1
  • MRc2.5

    Optimize use of alternative materials 1 / 1
  • MRc3.1

    Optimize use of IAQ compliant products 1 / 1
  • MRc3.2

    Optimize use of IAQ compliant products 1 / 1
  • MRc4.1

    Sustainable cleaning products and materials 1 / 1
  • MRc4.2

    Sustainable cleaning products and materials 1 / 1
  • MRc4.3

    Sustainable cleaning products and materials 0 / 1
  • MRc5.1

    Occupant recycling 1 / 1
  • MRc5.2

    Occupant recycling 0 / 1
  • MRc5.3

    Occupant recycling 0 / 1
  • MRc6

    Additional toxic material reduction - reduced mercury in light bulbs 1 / 1
  • EQc1

    Outdoor air delivery monitoring 0 / 1
  • EQc10.1

    Green cleaning - entryway systems 1 / 1
  • EQc10.2

    Green cleaning - isolation of janitorial closets 1 / 1
  • EQc10.3

    Green cleaning - low environmental impact cleaning policy 1 / 1
  • EQc10.4

    Green cleaning - low environmental impact pest management policy 2 / 1
  • EQc10.5

    Green cleaning - low environmental impact pest management policy 0 / 1
  • EQc10.6

    Green cleaning - low environmental impact cleaning equipment policy 1 / 1
  • EQc2

    Increased ventilation 1 / 1
  • EQc3

    Construction IAQ management plan 1 / 1
  • EQc4.1

    Documenting productivity impacts - absenteeism and health care cost im... 0 / 1
  • EQc4.2

    Documenting productivity impacts - other productivity impacts 0 / 1
  • EQc5.1

    Indoor chemical and pollutant source control - non-cleaning system re... 0 / 1
  • EQc5.2

    Indoor chemical and pollutant source control - non-cleaning - isolatio... 0 / 1
  • EQc6.1

    Controllability of systems - lighting 1 / 1
  • EQc6.2

    Controllability of systems - temperature and ventilation 1 / 1
  • EQc7.1

    Thermal comfort - compliance 0 / 1
  • EQc7.2

    Thermal comfort - permanent monitoring system 0 / 1
  • EQc8.1

    Daylight and views - daylight 1 / 1
  • EQc8.2

    Daylight and views - daylight 0 / 1
  • EQc8.3

    Daylight and views - views 1 / 1
  • EQc8.4

    Daylight and views - views 1 / 1
  • EQc9

    Contemporary IAQ practice 1 / 1
  • IOc1

    Innovation in upgrades, operations and maintenance + 4
  • IOc2

    LEED Accredited Professional + 1
  • Share on Twitter
  • Share on Facebook
  • Share on LinkedIn
  • Print

LEED Facts

for LEED O+M: Existing Buildings (v2.0)

Certification awarded Nov 2011

Gold
48
Sustainable sites
5/14
Water efficiency
3/5
Energy & atmosphere
8/23
Material & resources
13/16
Indoor environmental quality
14/22
Innovation
5/5