ID#
li-1083
| Credit Name | EQp2 - Environmental Tobacco Smoke (ETS) control |
|---|---|
| Credit Category | Indoor environmental quality |
| International Applicable | No |
Rating System
LEED BD+C: New Construction, LEED BD+C: New Construction, LEED BD+C: New Construction, LEED ID+C: Commercial Interiors, LEED BD+C: Core and Shell, LEED O+M: Existing Buildings, LEED O+M: Existing Buildings
Rating System Version
v2 - LEED 2.0, v2 - LEED 2.2, v2 - LEED 2.2, v2 - LEED 2.0, v2 - LEED 2.0, v2 - LEED 2.0, v3 - LEED 2008
Inquiry
The project, part of a HOPE VI development, is a six-story building containing 119 units of affordable housing. It employs non-combustible construction, interior partitions use metal stud framing. The project development team decided early in the process to render high performance and green in an affordable housing project even though this goal had not been proven in the local market. As compliance with the ETS control provisions is prerequisite, nothing short of the totality of this project\'s efforts toward LEED1/2 certification as well as all contingent funding is in the balance. The 12/3/2003 Credit Ruling describes an alternate compliance option that may be used in residential buildings. The performance target of 1.25 sq. in. equivalent leakage area per 100 sf. (ELA/100) of total enclosure area is beyond practicality for this project and may generally be so for other buildings of this type. Complex building systems coupled with accepted building practices inhibit continuous internal air(or smoke) separation between spaces. These difficulties multiply in steel construction where structural members and metal stud walls act like ducts connecting spaces within a building. Corrugated metal decks create conduit fields that impose monumental challenges to compartmentalizing by readily available products and skills. Abundant resources might be able to approach the nominal target, but such efforts may distract from more effective means to achieve the intent of the prerequisite. While a robust level of compartmentalization is essential for control of indoor air contaminants, control of pressure differences is also crucial. Each dwelling unit in this building has continuous mechanical exhaust of ~50 cfm and no other mechanical exhaust. Each apartment is also equipped with a dedicated outdoor air intake to help assure that make-up air is drawn directly from the exterior. With the residential ventilation system being direct, in-unit, and constant duty, the common area ventilation system is able to be more nearly balanced thus minimizing mechanically-induced pressure differences between corridors and other spaces as well as between floors. The building has a fluid-applied air barrier at exterior walls and a membrane roof that help to reduce the impact of exterior pressures acting on the building. The alternative compliance option references ASTM E779. We pose that ASTM E1827 is more relevant to the compliance option. It expressly provides guidance to the use of blower-door equipment, which has significant advantages in application to the ETS standard: - More widely available in region and significantly less costly than larger purpose-built pressure testing apparatus. - Multiple blower-doors are capable of inducing sufficient pressure to overcome background variability. It is unlikely that a building\'s mech. system would be able to induce such pressure unless it is enormously oversized. - Multiple blower-doors able to induce more even depressurization of whole buildings than a single fan. ASTM E779 indicates that "uniform pressure be maintained within the conditioned space to within +/-10% of the measured inside/outside pressure difference." There are also important differences between the standards\' measurement procedures. E779 requires multiple measurements across a range of pressures starting as low as 10 Pa. Measurements toward the lower end of the pressure range are subject to greater background variability and, therefore, have a de stabilizing effect on conclusions. E1827 provides a "Single-Point Method" that requires multiple measurements near 50 Pa. Project Proposes: Performance Target: 3.0 ELA/100. In combination with the ventilation strategy and exterior air barrier strategies, this performance target represents huge progress toward effective control of indoor air contaminants. It also requires substantial effort beyond standard industry practice. Methodology: "Single-Point" methodology described in ASTM E1827.