ID#

li-1167

Credit NameEQc4.2 - Low-emitting materials - paints and coatings
Credit CategoryIndoor environmental quality
International ApplicableYes

Rating System

LEED BD+C: New Construction, LEED BD+C: New Construction, LEED BD+C: New Construction

Rating System Version

v2 - LEED 2.0, v2 - LEED 2.2, v2 - LEED 2.2

Inquiry

In the spirit of Resource Reuse, we would like to maintain many of the existing clear finish birch doors. These interior birch wood veneer doors have an existing clear poly sealer. We understand that a water based clear sealers are not recommended for use over the existing oil based poly. The existing finish on the doors cannot be entirely removed because the surface veneer is too thin. The doors will be patched and lightly sanded to accept one coat of a compatible oil based clear sealer. It appears that most manufacturers all have oil base products that have VOC contents of approximately 450 grams/liter. We do not want to compromise the EQ 4.2 credit that the project anticipates achieving. The existing doors that are scheduled to be refinished represent a very very small percentage of the overall surface area that is scheduled for paints and coatings. We are using water based low-VOC products that comply with GS-11 where there are new wood surfaces and no-VOC paint throughout the project on all other surfaces. It is possible to refinish the existing doors off-site, if this would be considered to be a more environmentally friendly approach. We are aware that in 2004, the following credit interpretation was provided for a similar question (see below). It appears that coatings were exempt from the EQ credit 4.2 at the time. It appears that they are not exempt in 2005. For your reference: 7/29/2004 - Credit Interpretation Request We have a lot of cherry wood to be stained and sealed by hand in the building. All available stains and sealers have VOC over 150. I cannot find stain and varnish or polyurethane sealer that meets the VOC requirements specified. Please supply a list materials that can be used with applicable VOCs. We are currently painting the building and meeting all VOCs with Paint. The wood stained off site is meeting the VOCs because of the special process that are able to do at the factory. 9/23/2004 - Ruling The EQc4.2 Credit Ruling dated 12/22/2003 states: - The credit requirements and the referenced Green Seal GS-11 standard apply ONLY to opaque topcoat interior paint, such as that normally applied on walls. Stains and transparent finishes currently fall outside the scope of this credit. For projects wishing to address other coatings, additional low-VOC guidelines can be found in the California Air Resources Board Suggested Control Measures (CARB SCMs), available at: http://www.arb.ca.gov/coatings/arch/rules/ruleinfo.htm (most convenience way to view is in the Excel spreadsheet entitled "Summary of Architectural Coating rules and VOC limits for U.S. EPA, CARB SCM, Calif. Local Districts").

Logging out the application..