Created on LEED Interpretation

ID#

li-2051

Credit NameSSc8 - Light pollution reduction
Credit CategorySustainable sites
International ApplicableYes

Rating System

LEED BD+C: New Construction, LEED BD+C: New Construction, LEED BD+C: Schools, LEED BD+C: Schools, LEED BD+C: Core and Shell

Rating System Version

v2 - LEED 2.2, v3 - LEED 2009, v2 - Schools 2007, v3 - LEED 2009, v3 - LEED 2009

Inquiry

Because the criteria for Sustainable Sites Credit 8 have changed substantially from LEED-NC version 2.1 and version 2.2, this Credit Interpretation Request seeks guidance on whether CIRs issued for v2.1 would apply to similar situations under v2.2. The Tacoma Center for Urban Waters (TCUW) is a new 56,000 square foot office and laboratory building, located on the east side of the Thea Foss waterway in an area currently occupied by industrial uses. The ambient light level of this area is not high due to the fact that very little night use occurs. The TCUW will include facilities that are available to community groups and it is anticipated that a fair amount of after-hours use will take place. In addition, security for TCUW staff is a concern even during normal operating hours, as the Tacoma area experiences very short days during the winter months and it is anticipated that staff will arrive and leave in darkness for a significant part of the year. We have determined that the site qualifies as LZ3 - Medium (Commercial/Industrial, High-Density Residential) based on the current use of the surrounding area as well as the proposed use by TCUW. We would like to confirm that uplights which are shielded (i.e., located under an opaque canopy) would not count toward the percentage of allowable uplight under v2.2. We would also like to confirm that the principle outlined in the Columbia Heights CIR (12/1/2006) would apply to the TCUW project. The project includes a portion of the building that is set back from the property line by only 5 feet. The adjacent property is a narrow strip between our project and the city street that is used to park tanker trucks for the adjacent industrial uses. Our lighting of this area addresses two concerns. The first is security in this area, which does not receive any significant ambient lighting from surrounding properties or the street. Because views to the street are often blocked by parked trucks, the feeling of security in this area is very important. Also, the entire area between the building and the property line contains a sidewalk which also serves as path of egress to the public way. Our lighting scheme provides a maximum of 0.61 footcandles (fc) of horizontal illuminance and 1.0 fc of vertical illumination at the property line, which is also the curb line of the sidewalk. However, at 10 feet beyond the property line, light levels are 0.01 fc, with 0 fc at 15 feet beyond the property line. We have achieved this by utilizing a low-wattage (13 watt), wide-distribution fluorescent source, mounted at a low height (3.5 feet) on the building wall that adjoins the sidewalk. This fixture emits all light at angles below 90 degrees. All other components of the project comply with this credit, and we would like to confirm that our approach regarding the egress path lighting meets LEED\'s intent to reduce light pollution while allowing the project to meet code and security requirements.

Logging out the application..