Created on LEED Interpretation

ID#

li-2643

Credit NameSSc7.1 - Heat island effect - non-roof
Credit CategorySustainable sites
International ApplicableYes

Rating System

LEED BD+C: New Construction, LEED BD+C: Schools, LEED BD+C: Core and Shell, LEED O+M: Existing Buildings, LEED O+M: Existing Buildings

Rating System Version

v2 - LEED 2.2, v2 - Schools 2007, v2 - LEED 2.0, v2 - LEED 2.0, v3 - LEED 2008

Inquiry

This Credit Interpretation Request is for LEED-EB Sustainable Site Credit 6.1 Heat Island Effect, Non-Roof. The intent of the Credit is to reduce heat islands and minimize impact on microclimate, human habitat and wildlife habitat. The Credit can be achieved by providing a reduction in heat island effects caused by dark paved surfaces typically used in construction. There are four options (Options A, B, C & D) available that can be used to achieve the Credit. Although each option is based on a unique method of reducing heat island impacts (tree shading, high-albedo pavements, covered parking, and open grid pavement), none of the options allow for the combined benefits from these various methods of reducing heat island effects. Since these options represent unique methods of providing a reduction in heat island effects, a combination of these methods using more than one option can satisfy the intent of the Credit, and may provide more benefits than can be achieved by satisfying just one of the options. Our proposed method of achieving the credit utilizes high-albedo pavement (Option B), and underground / covered parking spaces (Option C), which are distinct areas that are not redundant. Not included in our approach is the tree shading provided throughout the site, which may further contribute to the reduction of heat island effects. The following calculations for Option B and Option C demonstrate how the combined benefits of high-albedo pavement and covered parking exceed the intent of the Credit. Option B - High-Albedo Pavement There is 179,303 SF of high-albedo concrete pavement on-site having a reflectance of 0.3 or greater. The total amount of non-roof impervious area is 912,560 SF. The percentage of high-albedo pavement is (179,303SF/912,560 SF) = 19.65%. Although this percentage is less than the 30% required to satisfy this Credit if used alone, it contributes significantly to the reduction of heat island effects, and should be counted as a contributing factor to satisfying the Credit. By using the ratio of the benefits achieved to the benefits required, this option satisfies (19.65%/30%) = 65.5% of the requirement. Option C - Underground Parking On the site there are 490 parking spaces underground. The total amount of parking spaces on site is 2075. The percentage of underground parking spaces is (490/2075) = 23.61% Although this percentage is less than the 50% required to satisfy this Credit if used alone, it contributes significantly to the reduction of heat island effects, and should be counted as a contributing factor to satisfying the Credit. By using the ratio of the benefits achieved to the benefits required, this option satisfies (23.61%/50%) = 47.2% of the requirement. Combined Options B & C The high albedo pavements on the site satisfy 65.5% of the requirements for Option B. The underground parking spaces on site satisfy 47.2% of the requirements for Option C. These two elements of the site contribute separately to heat island effects, and in this case these two elements are not redundant or overlapping. Therefore, working together these two options when combined create a reduction in heat island effects greater than reaching 100% satisfaction for just one of the options. The combined benefit that contributes to the reduction of heat island effects is 65.5% + 47.2% = 112.7%. Therefore, the intent of the Credit is satisfied, and the project should qualify for the Credit.

Logging out the application..