Created on LEED Interpretation

ID#

li-5088

Credit NameEAc1 - Optimize energy performance
Credit CategoryEnergy & atmosphere
International ApplicableYes

Rating System

LEED BD+C: New Construction, LEED BD+C: New Construction

Rating System Version

v2 - LEED 2.2, v3 - LEED 2009

Inquiry

Our project is located in Las Vegas and consists of a combination of office spaces and maintenance bays for earth-moving equipment. The owner is a large agency that sells, rents and repairs such equipment; these repairs are done both inside and outside the building envelope. The maintenance bays are occupied by mechanics and will be conditioned with evaporative coolers and gas furnace heat, the system supplies 100% outside air. This cooling system provides conditioning of the spaces but is not able to meet all peak loads for a climate such as Las Vegas even when these spaces are modeled with higher setpoint at 80 degrees. In reality, if the maintenance bays go above the temperature setpoints, the mechanics will continue work in the warmer conditions or take a break. This is not difficult for maintenance bays, where some of the work will also done outdoors with no conditioning at all. The owner does not want to fully condition the maintenance bays with the intention of achieving high levels of energy efficiency. We propose the following modeling approach for EA Credit 1. -Baseline model will have a mechanical system based on Table G3.1.1A of Appendix G with 80 degree temperature setpoint for the maintenance bays. -Proposed Design model will have the system as designed in the building that provides partial conditioning with the same 80 degree temperature setpoint. We will not model additional compressor cooling for hours where the system is not able to meet loads. This approach will result in exceeding the difference in the unmet load hours beyond 50 as required by Appendix G. However, this is a conscious decision by the owner who wants to maximize energy efficiency by providing limited conditioning through evaporative cooling for the maintenance bays, and allow the temperatures to float higher during peak conditions. We feel that this approach appropriately captures the intent of the design, and gives credit to the energy efficiency measures being taken. It also provides a way for demonstrating the value of an energy efficient approach to the community in Las Vegas where compressor cooling is increasingly used, often indiscriminately; this is a desert climate and a different approach to comfort and conditioning is possible. Is this approach acceptable? If not, can you advise us on an alternative approach that addresses the desire of the owner to demonstrate high levels of energy efficiency for using such a system?

Logging out the application..