Accessibility Tools

  • Increase text
  • Decrease text
  • High contrast
  • Negative contrast
  • Add grayscale
  • Remove grayscale
  • Add lightbackground
  • Remove lightbackground
  • Reset
Created on LEED Interpretation

ID#

li-5115

Credit NameEQp1 - Minimum IAQ performance
Credit CategoryIndoor environmental quality
International ApplicableNo

Rating System

LEED BD+C: New Construction, LEED BD+C: New Construction, LEED BD+C: Core and Shell, LEED BD+C: Core and Shell

Rating System Version

v2 - LEED 2.2, v3 - LEED 2009, v2 - LEED 2.0, v3 - LEED 2009

Inquiry

The project is designed to have about 60% of the building footprint as future tenant occupied datacenter space with the rest as support offices, shipping & handling office, corridors, restrooms, mechanical and electrical rooms. The datacenter will not be regularly occupied. The datacenter space will not have permanent or temporary workstations for the technicians. It is most similar in nature to an electrical or mechanical equipment room - technicians will be required to enter for short periods on an occasional basis for maintenance, etc. Additionally, the data center will be a sensitive area with access control (security), such that only authorized personnel may even enter the space. We would like to know if the datacenter space could be defined as a non-regularly occupied space & whether the proposed occupancy count for a datacenter space is appropriate. For LEED points concerning regularly occupied spaces: As per CIR Ruling 1/29/2008 (referred in LEED NC 2.2 credit EQ 6.2) & ASHRAE 62.1 2004, page 4 - definition of occupied space: "An enclosed space intended for human activities, excluding those spaces intended primarily for other purposes, such as storage rooms and equipment rooms, that are only occupied occasionally and for short periods of time." & As per CIR Ruling 1/29/2008 (referred in LEED NC 2.2 for credit EQ 8.1) - We consider the datacenter space as a non-regularly occupied space. We propose to exclude the datacenter space from the calculations of the following points: 1. EQ Prereq 1: Minimum IAQ Performance 2. EQ credit 1: Outdoor Air Delivery Monitoring 3. EQ credit 2: Increased Ventilation 4. EQ credit 6: Controllability of Systems, Thermal Comfort 5. EQ credit 7: Thermal Comfort, Compliance with ASHRAE 55-2004 (The data center will be designed to meet ASHRAE TC9.9 recommendations on Thermal Guidelines for Data Processing Environments.) 6. EQ credit 8.1: Daylight & Views Is datacenter a non-regularly occupied space? And, would the exclusion for the above points, be allowed? For datacenter occupancy count: As per LEED CS Appendix, default occupancy for a datacenter space is not listed. The technicians will enter the datacenter space occasionally and for short periods of time. Typically, we anticipate 1 technician for duration of 2 hours for 1 day, biweekly. At peak we anticipate 2 technicians for the same duration. So at any given time in the year there will be no more then 2 technicians in the datacenter space. We propose to: 1. Add the peak 2 datacenter occupants to the average transient occupancy & FTE for the regularly occupied areas for purposes of SS credit 4 calculations. 2. Add 2 transient occupants to the transient occupancy & FTE for the regularly occupied areas for purposes for WE credit 2 & 3 calculations. Is the above acceptable?

Logging out the application..