Created on LEED Interpretation

ID#

li-5178

Credit NameEAc1 - Optimize energy performance
Credit CategoryEnergy & atmosphere
International ApplicableYes

Rating System

LEED BD+C: New Construction, LEED BD+C: New Construction, LEED BD+C: Schools, LEED BD+C: Schools, LEED BD+C: Core and Shell, LEED O+M: Existing Buildings

Rating System Version

v2 - LEED 2.2, v3 - LEED 2009, v2 - Schools 2007, v3 - LEED 2009, v3 - LEED 2009, v3 - LEED 2009

Inquiry

Our project is a new 174,786 square foot refrigerated warehouse with interior offices. The office area will comprise approximately 8,800 square feet of the total building. The refrigerated portion of the building will be unoccupied and fully automated, maintained at -10 degrees Fahrenheit, and will include a receiving dock area maintained at +40 degrees Fahrenheit. For the baseline and actual energy performance calculations utilized for EAc1, we are proposing to calculate the office area and equipment of the building only, and exclude the refrigerated portion of the building. To clarify, the portion of the building under consideration includes the following elements: 1. Freezer Storage Area 2. Receiving Area (cold dock) a. Rail Access Vestibule b. Maintenance Room c. Storage Room d. Refrigerator Equipment Mezzanine e. Fire Pump/Sprinkler Room f. Electrical Room ASHRAE 90.1-2004 Section 2.3 states that the standard does not apply to "(c) equipment and portions of building systems that use energy primarily to provide for industrial, manufacturing, or commercial processes." The ASHRAE 90.1-2004 User\'s manual reinforces the point "for example, the Standard does not apply to refrigerated warehouses that are cooled to maintain the quality of the goods stored in the warehouse." We wish to clarify that for a refrigerated warehouse, the baseline and actual energy calculations for prerequisite EAp2 and credit EAc1 will be based on the office portion of the building only. All energy used for refrigeration in the previously described areas will be excluded from the calculations nor contribute to the required 25% process load. Note however, the envelope portion of the refrigerated warehouse will remain in full compliance with ASHRAE 90.1-2004 section 5. Please confirm that this approach is correct.

Logging out the application..