Created on LEED Interpretation

ID#

li-5235

Credit NameEAc1 - Optimize energy performance
Credit CategoryEnergy & atmosphere
International ApplicableNo

Rating System

LEED BD+C: New Construction, LEED BD+C: New Construction, LEED BD+C: Schools, LEED BD+C: Schools, LEED ID+C: Commercial Interiors, LEED BD+C: Core and Shell, LEED O+M: Existing Buildings

Rating System Version

v2 - LEED 2.2, v3 - LEED 2009, v2 - Schools 2007, v3 - LEED 2009, v3 - LEED 2009, v3 - LEED 2009, v3 - LEED 2009

Inquiry

Our project consists of multifamily rental units. We are performing the energy model using TRACE 700, a program that meets ASHRAE Standard 140-2004: Building Thermal Envelope and Fabric Load Tests. TRACE 700 does not have the capability of modeling domestic hot water energy usage. In order to account for domestic hot water energy usage we are proposing to use the Department of Energy sponsored Lawrence Berkeley National Laboratory calculation methodology. The spreadsheet can be found at www.doa.state.wi.us/docs_view2.asp?docid=2249. This spreadsheet estimates the energy consumption of water heaters based on power source, energy factor, and recovery efficiency. In addition, the spreadsheet estimates the energy reductions associated with hot water consumption of Energy Star clothes washers and dishwashers. According to the CIR ruling dated 4/25/2007, credit cannot be taken for low flow fixtures accounted for in WE credit 3. However, clothes washers and dishwashers are not accounted for in LEED NC v2.2 WE credit 3. An exceptional calculation in accordance with Appendix G will be provided to demonstrate energy savings for the Energy Star appliance itself. In addition, we believe the reduction in the amount of hot water required by Energy Star clothes washers and dishwashers should be accounted for in the water heating calculation. The basis for these calculations found at http://hes.lbl.gov/hes/aboutwhm.html will be uploaded as supporting documentation. 1. Can we use the Lawrence Berkeley National Laboratory spreadsheet since TRACE 700 does not model energy consumption for domestic water heaters? 2. Can the energy savings for the reduced hot water consumption for Energy Star clothes washers and dishwashers be accounted for in the domestic hot water energy consumption calculation?

Logging out the application..