ID#

li-5723

Credit NameWEc3.1 - Water use reduction - 20% reduction
Credit CategoryWater efficiency
International ApplicableNo
Campus ApplicableNo

Rating System

LEED BD+C: New Construction

Rating System Version

v2 - LEED 2.1

Inquiry

Our project is a 700,000 square foot health centre. Because of the varying occupant numbers in a hospital (including patients, staff and visitors) we propose an alternative method of calculating this credit. Rather than basing the calculations on the number of occupants, we have calculated our water use based on the total number of each type of applicable fixtures in the building and the estimated number of uses for each of these. For example, for the public W.C. our calculation is as follows: Total Daily Water Use (Public WC) = Total Number Of Fixtures x Estimated Daily Uses x Flow Rate(GPF) x Duration As required, our calculations use the same fixture count and daily use numbers for the base and proposed case. This should provide a reasonable representation of base and proposed case water use. As per previous rulings, our calculations include all flush fixtures and the following flow fixtures: - public and private lavatories - public and private showers - kitchen faucets - clinical, scrub up and service lavatories Also per previous rulings, we are excluding the following as process loads: - eyewash fountains, emergency showers, water coolers, and water fountains dishwashers etc. Please confirm that our approach is acceptable.

Logging out the application..