Created on LEED Interpretation

ID#

li-5908

Credit NameSSc7.1 - Landscape and exterior design to reduce heat islands - non-roof
Credit CategorySustainable sites
International ApplicableYes

Rating System

LEED BD+C: New Construction, LEED BD+C: New Construction

Rating System Version

v2 - LEED 2.0, v2 - LEED 2.2

Inquiry

The requirement of this credit states, "Provide shade (within 5 years) and/or use light-colored/high-albedo materials (reflectance of at least 0.3) and/or open grid pavement for at least 30% of the site\'s non-roof impervious surfaces, including parking lots, walkways, plazas, etc.; OR place a minimum of 50% of parking spaces underground or covered by structural parking; OR use an open-grid pavement system (less than 50% impervious) for a minimum of 50% of the parking lot area." We would like to clarify the use of porous pavement, that is, an asphalt or concrete surface with voids in the poured-in-place material designed to infiltrate water, as it relates to this credit. The third option of this credit clarifies the use of an open-grid pavement system as being less than 50% impervious, but LEED does not clarify a minimum amount of imperviousness for porous pavement, in this credit or other Sustainable Site Credits. (Note that a recent feature article in Environmental Building News describes a "void space" range of 15-21% for porous concrete, and 16-20% for porous asphalt, to be properly installed over uniformly graded stone aggregate having approximately a 40% void space). Does USGBC recommend a method to translate void space of porous pavement into % pervious for LEED Credits? Can we assume that if porous pavement were used rather than open grid pavement for 30% of the non-roof impervious area, that it could meet the first option of this credit? If used for 50% of the parking lot area, would it meet the third option of this credit? If its % pervious were determined to be less than 50% and therefore not equivalent to open-grid pavement, could its perviousness be averaged over a greater area, as would be consistent with the Credit Rulings related to material albedo? Lastly, if the material is pervious, how can it at the same time contribute to being 30% of our non-roof "impervious" surfaces for the first option of the credit? That reasoning would lead one to want subtract it from the denominator of this equation, leaving a smaller area that needs to be 30% LEED-compliant. Please advise in detail.

Logging out the application..